Most guidance on industrial solar assumes you own the whole building. On a multi-let estate you usually do not: the landlord owns the roof, a tenant pays for the electricity, and the lease sits between them. This page sets out who decides, who pays and who can claim the tax relief, so you know which conversation to have first. It is general information from an independent publisher, not legal or tax advice. The wider guide to solar panels for industrial units covers roofs, grid and tax; this page deals with the landlord-and-tenant side.
Which seat are you in?
| Seat | What you decide | First thing to read |
|---|---|---|
| Landlord | Whether to fit panels, let a tenant do it or bring in a third-party owner. | Each tenant’s lease: roof rights, repairs, service charge. |
| Managing agent | Nothing alone. You act on the landlord’s instructions. | Your written authority, then the lease and any head lease. |
| Full repairing and insuring tenant | Whether to ask, and whether to pay. | The alterations clause and what is included in the demise. |
| Owner-occupier | The lot, subject to your lender and insurer. | Your finance terms and any rights others hold over the roof. |
Consent: what the lease says
Fitting panels is normally an alteration to the roof, and most commercial leases make alterations to the structure or the roof a matter for the landlord’s written consent, often as a licence for alterations. Some leases bar them altogether; others allow them with consent not to be unreasonably withheld. Read the clause before you spend anything on design.
The Better Buildings Partnership Green Lease Toolkit (light, medium and dark green clauses) includes model wording on alterations and on renewable energy. Its model improvement-works clause is drafted on the basis that consent is not to be unreasonably withheld, but that only helps if your lease uses it. A consent that is silent on the end of the lease is not enough: agree in writing who owns the panels, who removes them and who makes good the roof.
Who pays, and who benefits
| Route | Who pays | Who gets the saving | What to settle |
|---|---|---|---|
| Tenant buys | Tenant | Tenant, through its own meter | Consent, roof access, removal and make-good at the end. |
| Landlord buys | Landlord | Landlord, or the tenant through a recharge or the lease terms | How any recharge works, and whether the service charge can cover it. |
| Third-party owner (power purchase agreement or roof lease) | The third party | The tenant buys the power; the landlord may receive rent for the roof | The term, the price per kWh and the end-of-term options. |
None of these is the default. On a multi-let estate the party paying for the roof work, the landlord, is rarely the party using the power, the tenant. A landlord can recover the cost of a landlord-funded installation through the service charge only if the lease covers it. Read the clause, and the RICS professional statement Service charges in commercial property (second edition, in effect from 31 December 2025), before you assume it can.
Who claims what
Capital allowances follow the money. Panels fixed to a building belong to the freeholder in law, but under the fixtures rules in Part 2, Chapter 14 of the Capital Allowances Act 2001 the person who incurs the expenditure and holds an interest in the land is treated as the owner for allowances, and a tenant with a lease counts. Only one person can claim for the same fixture, so agree who in the consent.
Solar PV is special-rate plant. The annual investment allowance (£1 million a year) can give 100% relief in year one for a business that has room under the limit, and companies can claim a 50% first-year allowance above it. Full expensing does not cover special-rate plant. Check your own position with an accountant. The seat-by-seat view is on the grants and funding page.
Business rates: in England, solar generating plant is left out of the rateable value from 1 April 2022 to 31 March 2035 under SI 2022/405, so fitting panels should not by itself raise the rates bill. That is an England-only rule. It does not apply in Wales, Scotland or Northern Ireland.
Multi-let estates: shared supply, shared roof
Check four things before design starts. Do the units share one incoming supply, and how is each metered? Is the roof one structure over several units, so that works over one tenant’s unit affect the next? Has the landlord’s insurer been told, and does it set conditions? Who has access to the roof, and when?
A connection above 16 A per phase needs a G99 application to the network operator, where a G98 notification covers smaller installations (see the Energy Networks Association). On a shared supply, agree who makes the application.
Why a landlord may raise it
One reason a landlord may bring up the roof with tenants: since 1 April 2023, non-domestic property let in England and Wales generally needs an EPC rating of at least E. The deadlines, exemptions and penalties are in the government guidance for landlords; they are not covered here.
Lease length against payback
Panels are a long-life asset, so the lease term matters. A tenant with a few years left may not recover its spend before the lease ends, and a landlord weighing a longer term in return for consent is trading certainty for payback time. Work out the payback against the years left, not against the life of the panels. The savings calculator gives an indicative size and saving from your floor area and daytime load; it is not a quote. If the lease is short, a landlord-funded system or a third-party owner can sidestep the problem, at the price of sharing the saving. For the wider verdict by occupier type, see is solar worth it for industrial units.
Planning, nation by nation
England. Class J of Part 14, Schedule 2 to the GPDO 2015 covers solar PV on non-domestic buildings. Arrays above the 50 kW microgeneration scale need prior approval from the council on design and external appearance, and listed buildings and scheduled monuments are excluded.
Wales. Part 43 Class A of the 1995 Order, inserted by WSI 2012/2318 and amended by WSI 2019/330, covers solar PV on non-domestic buildings, with a 3 km airport exclusion and a glint and glare condition.
Scotland. Class 6J of the Scottish permitted development order covers solar on non-domestic buildings; see Scottish Government Circular 2/2024 for the conditions.
Northern Ireland. It has its own planning rules; ask the council.